Reactions into pad sizes
In step 5, we used a Script node to turn the beam's bending moments into utilisations. In this step, we'll use a script in the same way to size the pad foundations under a portal frame. The script takes the base reactions from the model and works out the side of a square pad at each base, for an allowable bearing pressure of 150 kN/m². We'll also see where to put a value, such as the bearing pressure, that the calculation needs but the frame's analysis doesn't use.
1.0 The idea
To size a pad foundation, we need two numbers. These are the load the column applies to the pad and the allowable bearing pressure of the soil beneath it. The load comes from the model, as the vertical reaction at each base. Allowable bearing pressures are used with unfactored loads, so we use the reactions under the SLS combination rather than the ULS one.
The bearing pressure is a property of the ground, and it doesn't affect how the frame behaves. So, rather than make it a parameter of the model, we put it on the canvas as a Constant and wire it into the script. Changing the bearing pressure then changes the pad sizes without solving the model again. Changing the span is different, because the span changes the reactions, so each new span needs a solve.
2.0 The pad script
:
:
:
: : : : :