Showing the result on the model
In step 6, we painted a space frame roof by its buckling utilisation. In this step, we'll paint a four-storey steel frame of 248 members by its utilisation, and then by its axial forces, so that two load combinations can be compared colour for colour.
1.0 The idea
From a table of 248 utilisations, we can find that bx-A2-s1 is the most heavily utilised member. The painted frame also shows us where it is, and that the beams around it are almost as heavily utilised. Values of one sign get a sequential scale, as in step 6, and values of both signs, such as axial forces, get a diverging scale, blue through to red with zero in the middle.
2.0 The model
Our frame is 30 m by 18 m on plan, with 6 m bays and four storeys of 3.5 m. It has 120 nodes, rigid joints and fixed bases. Each member's name gives its type, grid line and storey, so col-B2-s1 is the column on grid line B2 in storey 1. Grid line A is the windward face.
The beams in X, UB 406 x 178 x 60, carry floors that span 6 m between them, and lighter ties in Y join the frames together. The three floors carry 5 kN/m² of dead load and 3 kN/m² of imposed load. The roof carries 3.5 kN/m² of dead load and no imposed load, and the ties carry 3 kN/m of dead load. A wind pressure of 1 kN/m² acts in X on grid line A, and it's applied as point loads at each floor level on that grid line. The loading is simplified for teaching, so there's no imposed load or snow on the roof, and the wind acts on the windward face only. The model has no self-weight case, so these are all the loads the frame carries.
3.0 The sheet
Press to open the sheet . Its first Markdown cell sets out the utilisation, the share of a member's yield strength used by its axial force and two bending moments,